Roof slope of 3 12.
1 hour roof truss assembly.
2x4 lumber oriented vertically or horizontally.
One hour roof ceiling assembly.
Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr.
I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control.
No minimum joist size is given except that it needs to be adequate for structural loads.
Figure 17 3 2 figure 17 3 2.
Engineered joist and truss.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
1 one hour and two hour rated assemblies that may be used in the roof cavity and that may be constructed with gable end frames.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
Ibctable 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses.
Wood truss council of america floor or roof fire notes 1.
I am looking for a 1 hour roof ceiling assembly for wood truss construction.
Ibc section 722 6 could be used to calculate up to a 1 hour rating for a wood frame wall floor or roof assembly.
With 1 25 mm type s drywall screws 12 305 mm o c.
5 8 15 9 mm toughrock fireguard c gypsum board or 5 8 15 9 mm densarmor plus fireguard c gypsum panels applied perpendicular to i shaped wood joists or wood and steel trusses spaced 19 2 488 mm o c.
Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
Pitched or parallel chord wood trusses spaced 24 max.
Through base layer perpendicular to.
Ibc table 722 6 2 2 allows 10 minutes for wood floor or roof joists at 16 o c.
Layer 3 trusses.
Maximum with 1 5 8 41 mm type s drywall screws 8 203 mm o c.
Assemblies include ducts dampers lighting or other fixtures in the tested assembly.
Truss depth shall be 5 1 4 with a min.
Figure 17 3 2 shows an alternative roof detail to that in figure 17 3 1 in which the roof trusses are parallel to the wall assembly.
With 1 2 wood structural panels with exterior glue applied at right angles to top of joist or top chord of trusses with 8d nails.
C roof ceilings45 51 steel framed including steel bar joist framing steel c joist framing steel truss and.
Fire safety building assembly s the period of time the assembly will serve as a barrier to the spread.
In this case a single layer of 1 2 gypsum wallboard is attached to the side of a single roof truss in the location shown to provide the required draftstop and area separation.
Is this possible without using channels and what ul number would i use.
Hr hour ht height insul insulating or insulation int interior lamin.
O c fabricated from nom.